Voltage Output Module (VOM)
The Voltage Output Module (VOM) provides analog and digital output data from VISION Calibration and Data Acquisition Software to any other external data acquisition module, such as a dynamometer control system.
Paired with a VISION Network Hub, the VOM is able to continue to transfer data as programmed even when users disconnect VISION from the project. This can be especially helpful in test cells when using the VOM to communicate to 3rd party DAQ hardware. The VOM can be used to monitor projects as it runs independently.
Product Features:
- 8 Analog Outputs
- 8 Digital Outputs
- Programmable Scaling and Offset
Inputs/Outputs
Operating Conditions
Inputs/Outputs
Outputs/Inputs
Number of Analog Channels | 8 |
Analog Range | 0-5 V or 0-10 V (intended for high impedance inputs only) |
Analog Resolution | 12 bits |
Analog Accuracy | +/- 10 mV |
Analog Speed | 100 Hz |
Number of Digital Channels | (8) channels with front panel LED indicators |
Digital Voltage | 0-5 V |
Digital Current | 1 mA |
Operating Conditions
Operating Conditions
Communications | High-speed CAN |
Connectors | Analog & Digital outputs: DB25 DC Power & CAN: LEMO 1B-Series 5-pin |
Power Supply | 9-32 VDC |
Current | 300 mA (4 W) |
Temperature Range | -40 °C to +85 °C / -40 °F to +185 °F |
Dimensions | 135 x 93 x 29 mm / 5.31 x 3.66 x 1.14 in |
Weight | 335 g / 11.8 oz |
Accessories
EDAQ to EDAQ
Cable
150-0017/18/19
180° angle connectors (1.83 m/6 ft, 3.66 m/12 ft or 10.1 m/33 ft)
Contact your local sales office for purchasing details
HUB to EDAQ
Cable
150-0021/22/23
90°/180° connectors (3.66 m/12 ft, 10.1 m/33 ft or 1.83 m/6 ft)
Contact your local sales office for purchasing details
U Adapter
(Hub/VOM)
150-0024
Joins CAN connectors for stacked VISION Hub and VOM; 90° 5-pin LEMO 1B connectors
Contact your local sales office for purchasing details
All specifications are subject to change without notice.